Bovine Sepiapterin reductase (SPR) ELISA Kit
Species Reactivity : Bovine (Bos taurus; Cattle)
UniProt : Q17QK8
Abbreviation : SPR
Alternative Names : SDR38C1; sepiapterin reductase|short chain dehydrogenase/reductase family 38C; member 1
Application : ELISA
Range : 0.312-20 ng/mL
Sensitivity : 0.108 ng/mL
Intra-AssayCV : ?6.2%
Inter-AssayCV : ?10.8%
Recovery : 1.05
Sample Type : Serum, Plasma, Other biological fluids
Detection Method : Sandwich
Analysis Method?? : Quantitive
Test principle : This assay employs a two-site sandwich ELISA to quantitate SPR in samples. An antibody specific for SPR has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and anySPR present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conj µgated antibody specific for SPR is added to the wells. After washing, Streptavidin conj µgated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of SPR bound in the initial step. The color development is stopped and the intensity of the color is measured.
Product Overview : Sepiapterin reductase (7,8-dihydrobiopterin : NADP+ oxidoreductase; EC 1.1.1.153) catalyzes the NADPH-dependent reduction of various carbonyl substances, including derivatives of pteridines, and belongs to a group of enzymes called aldo-keto reductases. SPR plays an important role in the biosynthesis of tetrahydrobiopterin (BH4). The clone encoded a protein of 261 amino acids with a calc µLated molec µLar mass of 28,047 Da. The predicted amino acid sequence of human sepiapterin reductase shows 74% identity with the rat enzyme and a striking homology with human carbonyl reductase, estradiol 17-beta-dehydrogenase, and 3-beta-hydroxy-5-ene steroid dehydrogenase, especially in the N-terminal region.
Stability : The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. The loss rate was determined by accelerated thermal degradation test. Keep the kit at 37°C for 4 and 7 days, and compare O.D.values of the kit kept at 37°C with that of at recommended temperature. (referring from China Biological Products Standard, which was calc µLated by the Arrhenius equation. For ELISA kit, 4 days storage at 37°C can be considered as 6 months at 2 - 8°C, which means 7 days at 37°C equaling 12 months at 2 - 8°C).